SECTION 230545 - SEISMIC RESTRAINTS FOR HVAC PIPING & EQUIPMENT
SEISMIC RESTRAINTS FOR HVAC PIPING AND EQUIPMENT. S:\\MASTERS\\DIV-23\\230545MT.DOCX. 230545-3. SEISMIC RESTRAINTS FOR HVAC PIPING AND EQUIPMENT. Piping 1 1/4 inches nominal diameter and larger located in mechanical equipment rooms. Piping 2 1/2 inches nominal diameter and larger. ... Retrieve Content
USA - WBDG Whole Building Design Guide
VISCMA 412 (2014) Installing Seismic Restraints for Mechanical Equipment 1.2 SYSTEM DESCRIPTION 1.2.1 General Requirements ***** NOTE: Designer should verify that specified details do not interfere with the performance of the cathodic protection system (when used) or of the ... Read Content
Smacna Seismic Restraint Manual Guidelines For Mechanical Systems
Smacna Seismic Restraint Manual Guidelines seismic restraint of equipment, piping and ductwork. Contractors' National Association, Inc. Guidelines for Seismic Restraints of Mechanical Systems", Mason, or equal. Systems," and aboveground steel piping both outside SMACNA 1981 (2008 ... Access Doc
Elements Of 2012 IBC - ASCE 7-10 Nonstructural Seismic ...
Keywords: nonstructural, equipment, systems, seismic requirements, building codes 1. ELEMENTS OF MODEL BUILDING CODES Nonstructural building code provisions in the United States have adopted sweeping changes over the mechanical and electrical components. The mechanical and ... Fetch This Document
Proposed Canadian Code Provisions For seismic Design Of ...
Components, and equipment1 W.E. McKevitt Abstract: Proposed code provisions for the seismic design of elements of structures, nonstructural components, and equipment are presented. In these provisions a new format is introduced which gives a consistent treatment for all ele-ments and components, architectural, mechanical, and electrical. ... Get Content Here
6.4.1 Mechanical Equipment
Roof. If the equipment is internally isolated, the design forces for the anchorage should be increased appropriately. See FEMA 412 Installing Seismic Restraints for Mechanical Equipment (2002) and FEMA 414 Installing Seismic Restraints for Duct and Pipe (2004) for details for wall-mounts, ... Return Doc
SECTION 01451 SEISMIC CONTROL - Health.ucdavis.edu
Installation of all architectural, mechanical, and electrical equipment/components are in compliance with all applicable seismic codes, standards, and specific information listed seismic restraints) shall be limited so as not to overload the building structure and the support assembly. 12 ... View This Document
HVAC Sound Vibration And Seismic Control - Laschools.org
1. Refer to Seismic Restraint Manual: Guidelines for Mechanical Systems, published by SMACNA and approved by DSA, for minimum seismic restraints required on mechanical components design and construction details. 2. Provide seismic restraints for mechanical equipment or components specified. ... View This Document
INSTALLING SEISMIC RESTRAINTS FOR DUCT AND PIPE
INSTALLING SEISMIC RESTRAINTS FOR DUCT AND PIPE. ii iii INSTALLING SEISMIC RESTRAINTS FOR DUCT AND PIPE January 2004 Developed by the Vibration Isolation and Seismic Control Equipment Brackets or Additional Steel Supports 84 Suspended by Steel Shapes 95 ... Fetch Doc
Seismic Design And Retrofit Of Piping Systems July 2002
Seismic Design and Retrofit of Piping Systems AmericanLifelinesAlliance A public-private partnership to reduce risk to utility and transportation systems from natural hazards Seismic Design and Retrofit of Piping Systems July 2002 www.americanlifelinesalliance.org This report was written under contract to the American Lifelines ... View This Document
Structural Engineering - Wikipedia
Structural engineering is a sub-discipline of civil engineering in which structural engineers are trained to design the 'bones and muscles' that These works can require mechanical structural engineering: Boilers and pressure vessels; Coachworks and carriages Medical equipment (also known ... Read Article
20 30 13 - Vibration Isolation And Seismic Control For ...
B. Provide the types of vibration isolation devices as recommended by the respective mechanical equipment manufacturers, to isolate vibrations for each particular piece of equipment. The isolator type seismic restraints shall, as a minimum, consist of VIBRATION ISOLATION AND SEISMIC ... Retrieve Here
Pipe Support - Wikipedia
A pipe support or pipe hanger is a designed element that transfer the load from a pipe to the supporting structures. Seismic Load : Seismic load is one Mechanical Snubber: ... Read Article
SECTION 15241 - MECHANICAL VIBRATION CONTROLS AND SEISMIC ...
Such mechanical equipment shall be properly supported to resist a horizontal force of 50 percent of the weight of the equipment furnished. All mechanical equipment mounted on vibration isolators shall be provided with seismic restraints capable of resisting a horizontal force of 100 percent of the weight of the equipment furnished. ... Content Retrieval
SEISMIC RESTRAINT MANUAL - Iccsafe.org
Mechanical systems could mean that a building might be uninhabitable for weeks or months. As a result, seismic con- cerns now include restraints for ductwork and piping in buildings. ... Fetch Here
STANDARD NYC SEISMIC NOTE - Abraham Joselow Pe
Seismic protection of all HVAC equipment, piping and ductwork shall be provided and shall comply with the The designD of seismic restraints for sprinkler piping in compliance with NFPA 13 using a design acceleration of 0.15 is Piping in boiler and mechanical rooms which has less than 1-1 ... Doc Viewer
Restraining Building Services Systems Against Explosive ...
Jim covers how mechanical systems can be practically braced against explosive blasts and seismic incidents. He includes examples of piping, ductwork, suspended and floor supported equipment. ... View Video
Seismic Restraint Of Engineering Services - AIRAH
Engineering Services This presentation will cover: • Design of Seismic Restraints • Seismic Restraint examples Christchurch, Sept 2010 . The Earthquake Hazard . Earthquakes • The earth’s outer shell is about 100-200 kilometres thick and is Mechanical, electrical and ... Access Document
Seismic Control Kinetics KSCA Cable Attachment Bracket Spring ...
Port and emergency equipment is limited, and the equipment remains in position. Anchorage of Model FHS isolators should be designed by a professional engineer and isolators selected based on calculated anticipated forces. KINETICS Seismic Restraint for Isolated and Suspended Mechanical Equipment TM KINETICS Floor-Mounted Seismic Restraints TM ... Fetch Content
SECTION - MECHANICAL VIBRATION AND SEISMIC CONTROLS GENERAL ...
Structural member size, support point, vibration isolators and seismic restraints. 3. Seismic restraint and anchor calculations signed and stamped by a professional engineer. 4. Drawings indicating methods for suspension, support, seismic restraints, guides, etc., for piping and ductwork. 5. Mechanical, electrical and plumbing equipment ... Read Full Source
Design Standard Vibration And Seismic Controls For HVAC ...
− Design the seismic bracing and anchorage of piping per Section 23 05 29 − Design piping and ductwork seismic restraints using the document "Seismic Restraints Manual Guidelines for Mechanical Systems." Secure piping, equipment, ductwork, and the like to withstand a force in any direction. ... Retrieve Here
No comments:
Post a Comment